VOLTAGE TEST
STATION
Enhance your electrical safety
program through safety-by-design.
VOLTAGE TEST STATION FEATURES
▶▶ The Voltage Test Station (VTS) is a Permanent Electrical Safety
Device that allows workers to quickly and safely validate zero electrical energy from outside the electrical enclosure.
▶▶ The VTS combines a voltage indicator and test points to confidently verify zero electrical energy.
▶▶ Provides a safer and more productive method of performing
LOTO, while exceeding NFPA 70E and meeting OSHA energy isolation principle.
▶▶ Lockable housings add an additional layer of protection by
allowing authorized personnel to safely access the VTS.
FOR MORE INFORMATION VISIT PESD.COM
Component
Code
P-R3W-R-3MT
TEST POINT UNIT
NEMA Housing Exception
Option
Code
OPERATION
The R-3W series provides visibility of voltage using flashing (R-3W/2) and non flashing (R-3W-SR)
LEDs to visually verify zero electrical energy without any exposure to voltage inside the electrical panel.
The R-3MT contains four test point jacks that can measure AC or DC voltages using facilities safety
procedures by inserting insulated meter probes with .080” tips into any two test point jacks to take a
voltage reading. The meter must be rated to withstand the maximum applied AC or DC voltage and have
typical 10 MΩ input impedance.
The Voltage Test Station (VTS) takes the guess work out of verifying electrical energy and enhances
your work place safety and productivity.
P-S10S21-M2RX-V
TECHNICAL SPECIFICATIONS
Component Code
S10
S11
S12
S21
Series
R-3W
R-3W2
R-3W-SR
R-3MT
Operating & Storage
-45°C to +85°C
Operational Range
AC Single or 3-Phase
40-750VAC
50/60/400Hz
40-600VAC
50/60/400Hz
Operational Range
DC or Stored Energy
40-750VAC
50/60/400Hz
0 to 600VAC
Line-to-Line or Line-to-Ground
30 to 1000 VDC
750VAC/1000VDC
0 to 1000VDC, any (2) wires
Line-to-Line or Line-to-Ground
Internal Resistance
N/A
102 kΩ 6 Watt, 5% Tolerance in
series with each input (L1,L2,L3) wire
to respective output jack maximum
momentary
Output Accuracy
N/A
+/- 2% of Applied Input Voltage
10 MΩ input impedance volt meter
connected to any (2) test points
Correction Factor
N/A
1.02 x Test Point
Voltage Reading
NEMA HOUSING OPTIONS
NEMA Type*
Housing Code
4
M2
M3
4X
12
x
x
M4
x
Dimensions
L
W
D
in/mm
(overall)
in/mm
(overall)
in/mm
(internal)
6.50
[165.0]
3.78
[96.0]
2.50
[64.0]
6.50
[165.0]
3.78
[96.0]
2.50
[64.0]
6.50
[165.0]
3.78
[96.0]
2.50
[64.0]
M5 (#304SS)
x
6.0
[152.0]
4.0
[102.0]
2.0
[51.0]
M6 (#316SS)
x
6.50
[152.0]
4.0
[102.0]
2.0
[51.0]
Housings available with exception code V (Vertical Layout)
R-3MT TERMINATIONS
▶▶
▶▶
▶▶
▶▶
▶▶
▶▶
▶▶
▶▶
▶▶
▶▶
3 Red Jacks
1 Green Insulated Jack
.080” DIA Pin Sockets
Corrosion Resistant Beryllium Copper
4 Wires
8 ft
18 AWG
90ºC @ 1000V
UL-1452
PVC Insulated w/ Nylon Jacket
1.549”
39.34mm
0.530”
13.47mm
0.530”
13.47mm
* Not UL listed
FOR MORE INFORMATION VISIT PESD.COM
D-S10S21-DS 062015
R-3MT TEST POINTS
Warning: Verify an electrical conductor has been de-energized using an adequately rated voltage detector before working
on it. Follow appropriate Energy Control (Lockout/Tagout) procedures as per OSHA Subpart S.
© Grace Engineered Products, Inc. All rights reserved. Specifications are subject to change with/without notice.
×