Model No.: PCM Type:xzd-3S1550-V3
PRODUCT SPECIFICATION
CONFIDENTIAL
SPECIFICATION
OF
PCM Type: XZD-3S1550-V3
Approved by
Checked by
Xiaopeng Chen
Prepared by
Lujin An
KEEPPOWER TECHNOLOGY CO., LIMITED
Add:Bldg C, Hepingang High Tech Park, LongGang, Shenzhen 518129, China
Tel: +86 755 8930 9658 Fax: +86 755 8930 9659
www.keeppower.com.cm
Model No.: PCM Type:xzd-3S1550-V3
PRODUCT SPECIFICATION
CONFIDENTIAL
1. Scope
The specification is applied to the protection of three-cell lithium-ion battery pack from
overcharge, over-discharge and excess current.
2. Specification
2.1 Name: XZD-3S1550-V1
(4MOS)
2.2 Circuit Schematic Diagram:
Refer to Figure 1.
2.3 PCB Form Diagram: Refer to Figure 2.
2.4 PCB Material: FR4 (50.0mmx15.0mm)
2.5PCB Size Form Diagram Refer to Figure 3
2.6PCB Connect Form Diagram Refer to Figure 4
3. Electric Characteristics (Ta=25℃)
3.1 Overcharge detection voltage(VCU):
4.275±0.05V
3.2 Overcharge detection delay time:
1.0±0.5m S
3.3 Overcharge release voltage:
4.075±0.05V
3.4 Under-discharge detection voltage(VDD):
2.30±0.10V
3.5 Under-discharge detection delay time:
1.0±0.5 mS
3.6 Under-discharge release voltage:
2.70±0.1V
3.7 Excess current threshold (IEC):
10A-18A
3.8 Maximum Continuous Current
5-6A
3.9 Short detection delay time:
MAX.18mS
3.10 Supply current (V cell=3.5V) :
MAX.10μA
3.11 Standby current(V cell=1.8v) :
MAX. 1uA
3.12 PCB total resister:
MAX. 55mΩ
4. Function Description
4.1 The PCB is applied to protection of three-cells lithium-ion battery pack, which is set
according to requirement of customer.
4.2 Overcharge protection:
The overcharge protection operates when voltage of cell more than VCU with charger at P+
and P-, then charge will be stopped and discharge will be allowed.
Model No.: PCM Type:xzd-3S1550-V3
PRODUCT SPECIFICATION
CONFIDENTIAL
4.3 Over-discharge protection:
The over-discharge protection operates when voltage of cell more than VDD with load at
P+ and P-, then discharge will be stopped and charge will be allowed.
4.4 Excess current protection:
The Excess current protection operates when current more than IEC with load at P+ and P-,
then discharge will be stopped and charge will be allowed.
5. Parts List
Name
Quantity
Reference
Part
CAP
6
C1,C2, C3, C4, C5, C7
0.1uf /0603
RES
2
R1, R3
5.1kΩ±5%/0603
RES
1
R2
1MΩ±5%/0603
RES
6
R5, R6,R7,R8,R9,R10,R11
1kΩ±5%/063
RES
1
R117
51Ω±5%/0805
RES
2
R14,R?
10mΩ±5%/1206
IC
1
U1
S-8254-AAG
MOSFET
4
PCB
PQ1,PQ2, PQ3,PQ4
AO4407
50*15mm
PRODUCT SPECIFICATION
CONFIDENTIAL
Figure 1 Schematic Diagram
Model No.: PCM Type:xzd-3S1550-V3
PRODUCT SPECIFICATION
CONFIDENTIAL
Figure 2 PCB Form Diagram
Figure 3 PCB Size Form Diagram
Model No.: PCM Type:xzd-3S1550-V3
PRODUCT SPECIFICATION
CONFIDENTIAL
Figure 4 PCB Connect Form Diagram
Model No.: PCM Type:xzd-3S1550-V3