Residential Distribution Solutions
Beautifully simple
2
one
all in
3
Our solutions for
Residential
buildings
“Hager’s residential distribution solution
ensures you have everything you need for
your next installation. The combination
of our award winning and aesthetically
pleasing golf enclosure range coupled with
our onekonekt system, provides you with
a beautfully simple solution that makes
each installation easier, safer and faster.”
Everything in the system
golf enclosures
golf Home Networking enclosures
The golf enclosure is the perfect solution for all residential and
multi-residential installations. The enclosure is swiftly and easily
mounted and offers space for a large number of modular devices.
The golf Home Networking enclosure offers solutions
that provide you with the greatest amount of flexibility
to meet almost any type of home networking equipment.
The advantages for you
 Flush or Surface mount, opaque or transparent door
options available
 1 to 4 rows from 4 to 72 modules
 Ample wiring space between the modular devices
and terminals as well as behind the DIN rails
 Clean and convenient wiring thanks to
patented integrated cable management system
The advantages for you
 Flush mount with opaque door design,
consistent with golf enclosures
 3 sizes and extension box available
 Easy installation, can be turned 180o
to install patented slider on top or bottom
 Ample wiring space allows room to mount peripherals
4
Modular
Protection Devices
Hager’s full range of
residential protection devices
connect to the same busbar
increasing safety and
reducing installation time.
The advantages for you
 All earth leakage devices
are type-A increasing fault
identification
Link Terminals
Our Link terminals
offer significant time
saving and reliability
compared to traditional
brass link screw terminals.
The advantages for you
 Quick and easy screwless
installation
 Rerliable and constant
tension reduces potential
hot joints
 Easy labelling system for
clear circuit identification
Network Accessories
Sliders
Hager’s patching solutions
allow both multi and single
module add-ons in Cat5,
Cat6 and shielded.
Our patented sliders keep
unsightly wires contained
behind the wall and help
to provide power to our
networking enclosures.
The advantages for you
 Additional Cat5, Cat6 and
F-type modules available
 4 and 8 outputTelephone
splitters for simple distribution
Individual toolless Cat6
patch modules
The advantages for you
 The double slider is used
to connect a golf mains
distribution enclosure to
a golf home networking
enclosure creating a unique
combination
5
beauty
outside
6
7
Innovation
on the inside
The golf enclosure range from Hager is the benchmark in distribution. Packed with features that provide
simple and fast installation, available in flush or surface mounting and with a choice of either Link
terminals, 63A or 100A brass links, this red dot design award and Australian International Design Award
winning range meets all expectations in distribution for both contractors and home owners.
8
Quality
Adaptability
Reliability
Options
Our surface mount golf
enclosures with their ample
cabling space, convenient
cable management,
installation tips within the
box and the ability to rotate
the enclosure a full 180o,
means they are ideal for any
standard residential power
distribution installation.
Hager’s flush mount golf
enclosures have the added
advantage of connecting to
our golf home networking
enclosures to provide
a comprehensive and
aesthetically pleasing solution
for any residential installation.
Optional patented neutral
& earth
link terminals
provide an easier, safer
and faster connection
for your installation,
saving time & money.
All golf enclosures are
supplied with standard
63A brass links with the
option of 100A where
higher ratings are needed.
9
10
speed
high
11
High performance,
high safety
Our onekonekt residential range of modular devices saves you time and money,
with an installation time up to 10 times faster than traditional wiring.
The onekonekt system is one of the most versatile & flexible solutions to residential electricians on the
market today. The use of busbar in our industry is not a new concept. However, providing a full range of
residential protection devices that connect to the same busbar, increasing safety, reducing installation
time, improving technical characteristics and aesthetics within one system, definitely is.
12
Safety
Performance
Flexibility
Simplicity
Insulated fork caps enable
unused forks to remain
in-situ for additional circuits
in the future. Busbar and
endcaps ensure complete
insulation of the bar.
Our type A Earth Leakage
Devices filter out interference
from modern day appliances
such as TV’s washing
machines and LED lighting,
that can potentially prevent
the device from operating
accurately.
Bi-connect terminals on
all devices enable supply
from either cables in the
cage or busbars in the
slot; guaranteeing full
connection capacity.
For the entire 2 pole RCCB
and RCBO range, the neutral
busbar slot is fully insulated
so there is no need to cut
the forks off the busbar.
13
connect
easy to
14
15
A new approach
to home networking
Australians love technology. Our homes are now filled with multiple users, home offices,
smart TVs, game consoles, smart phones and more. Today, the creation of a home network
has become more of a need than a luxury.
Hager’s golf home networking enclosure is a first in Australia, providing the option
to be installed as a stand-alone home network hub or combined with the mains distribution
golf enclosure by utilising our patented double slider providing you with pure aesthetic genius.
16
Versatility
Circulation
Flexibility
Additions
Three flush mount enclosure
sizes supply ample space for
mounting all your network
distribution modules as
well as other peripherals.
The vented door assists with
heat dissipation and assists
signal reception for wireless
devices mounted within.
With the use of our
patented double sliders,
you can combine your
mains distribution with
your home networking
for ease of cabling and
superb aesthetics.
Cat 6 UTP/STP individual
patch modules and 4 to 8
way telephone splitter helps
simplify every installation.
17
Beautifully simple,
the complete system
At Hager, we believe that every home owner deserves to have a high quality, safe and great looking
distribution system in their home - and the installation of the system should be simple and beneficial
to all installing contractors.
The golf system offers exactly that. From its award winning aesthetics on the outside, to it’s
installer friendly, superior protection and distribution equipment on the inside, it’s the most flexible,
comprehensive solution on the market today.
18
•
•
golf VS series enclosures
Surface mounted
with brass terminals
20
Surface mounted
with
link terminals
21
golf VF series enclosures
Flush mounted
with brass terminals
22
Flush mounted
with
link terminals
23
•
golf enclosure accessories
24
•
Home networking modules
25
•
Home networking accessories
26
•
Isolating switches
27
•
MCB’s
28
•
RCBO’s
29
•
Safety switches
30
•
Insulated busbars & connectors
31
•
golf enclosure technical summary
32
•
onekonekt technical summary
33
19
golf VS series enclosures
Surface mounted with brass terminals
Surface mounted distribution
boxes from 1 to 4 rows, from
4 to 72 modules, supplied
with opaque or transparent
door for devices up to
70mm installation depth.
Door can be fitted on right or
left, optional lock and keys.
Door opens up to 180º.
Wall box and cover are
symmetrical for removable
cable entry slider. Cable
entries for cable and conduit.
VS Components:
- Earth & neutral terminals
- Pole fillers
- Patented marking system
- Cable management clips
- Transport protection film
- Busbar supplied with
some references
Technical data:
- IP rating:
IP30 without door
IP40 with door
IK07
- Isolation Class II
- White colour RAL 9010
- Rated current:
for devices up to 63A
- Rated insulation voltage:
400V AC/50Hz
Standard: all products
conform to Australian and
international standards.
All products conform to the
RoHS and WEEE directives.
golf enclosure with 63A brass terminals
Description
VS112PT
VS218PT
1 row 4 I
1 row 8 I
1 row 12 I
1 row 18 I
2 row 24 I
2 row 36 I
3 row 36 I
3 row 54 I
4 row 48 I
4 row 72 I
Busbar
None
None
1 x 12 pole
1 x 18 pole
2 x 12 pole
2 x 18 pole
3 x 12 pole
3 x 18 pole
4 x 12 pole
4 x 18 pole
Brass terminal
25mm2
16mm2
10mm2
1
1
1
1
1
1
1
1
2
1
2
4
8
12
14
21
16
21
26
21
3
5
9
13
16
24
17
24
28
24
Cat ref.
Opaque Door
Cat ref.
Transp. door
VS104PT
VS108PT
VS112PT
VS118PT
VS212PT
VS218PT
VS312PT
VS318PT
VS412PT
VS418PT
VS104TT
VS108TT
VS112TT
VS118TT
VS212TT
VS218TT
VS312TT
VS318TT
VS412TT
VS418TT
golf enclosure with 100A brass terminals
VS318TT
VS412TTH
20
Description
Busbar
Cat ref.
Opaque Door
Cat ref.
Transp. door
1 row 12 I
1 row 18 I
2 row 24 I
2 row 36 I
3 row 36 I
3 row 54 I
4 row 48 I
4 row 72 I
1 x 12 pole
1 x 18 pole
2 x 12 pole
2 x 18 pole
3 x 12 pole
3 x 18 pole
4 x 12 pole
4 x 18 pole
VS112PTH
VS118PTH
VS212PTH
VS218PTH
VS312PTH
VS318PTH
VS412PTH
VS418PTH
VS112TTH
VS118TTH
VS212TTH
VS218TTH
VS312TTH
VS318TTH
VS412TTH
VS418TTH
golf VS series enclosures
Surface mounted with link terminals
Surface mounted distribution
boxes from 1 to 4 rows, from
4 to 72 modules, supplied
with opaque or transparent
door for devices up to
70mm installation depth.
Door can be fitted on right or
left, optional lock and keys.
Door opens up to 180º.
Wall box and cover are
symmetrical for removable
cable entry slider. Cable
entries for cable and conduit.
VS Components:
- Earth & neutral terminals
- Bridging clips
- Pole fillers
- Patented marking system
- Cable management clips
- Transport protection film
- Busbar supplied with
some references
golf enclosure with
Description
VF218PT
1 row 12 I
1 row 18 I
2 row 24 I
2 row 36 I
3 row 36 I
3 row 54 I
4 row 48 I
4 row 72 I
Technical data:
- IP rating:
IP30 without door
IP40 with door
IK07
- Isolation Class II
- White colour RAL 9010
- Rated current:
for devices up to 63A
- Rated insulation voltage:
400V AC/50Hz
Standard: all products
conform to Australian and
international standards.
All products conform to the
RoHS and WEEE directives.
link terminals
Busbar
1 x 12 pole
1 x 18 pole
2 x 12 pole
2 x 18 pole
3 x 12 pole
3 x 18 pole
4 x 12 pole
4 x 18 pole
link terminal
25mm2
4mm2
3
4
4
7
7
10
10
15
15
20
20
29
29
42
36
55
Cat ref.
Opaque Door
Cat ref.
Transp. door
VS112PTQ
VS118PTQ
VS212PTQ
VS218PTQ
VS312PTQ
VS318PTQ
VS412PTQ
VS418PTQ
VS112TTQ
VS118TTQ
VS212TTQ
VS218TTQ
VS312TTQ
VS318TTQ
VS412TTQ
VS418TTQ
21
golf VF series enclosures
Flush mounted with brass terminals
Flush mounted distribution
boxes from 1 to 4 rows, from
4 to 72 modules, supplied
with opaque or transparent
door for devices up to
70mm installation depth.
Door can be fitted on right or
left, optional lock and keys.
Door opens up to 180º.
Wall box and cover are
symmetrical for removable
cable entry slider. Cable
entries for cable and conduit.
VF Components:
- Earth & neutral terminals
- Pole fillers
- Patented marking system
in enclosures >36 I
- Cable management clips
in enclosures >36 I
- Transport protection film
- Busbar supplied with
some references
Technical data:
- IP rating:
IP30 without door
IP40 with door
IK07
- Isolation Class II
- White colour RAL 9010
- Rated current:
for devices up to 63A
- Rated insulation voltage:
400V AC/50Hz
Standard: all products
conform to Australian and
international standards.
All products conform to the
RoHS and WEEE directives.
golf enclosure with 63A brass terminals
Description
VF112PT
VF218PT
1 row 4 I
1 row 8 I
1 row 12 I
1 row 18 I
2 row 24 I
2 row 36 I
3 row 36 I
3 row 54 I
4 row 48 I
4 row 72 I
Busbar
None
None
1 x 12 pole
1 x 18 pole
2 x 12 pole
2 x 18 pole
3 x 12 pole
3 x 18 pole
4 x 12 pole
4 x 18 pole
Brass terminal
25mm2
16mm2
10mm2
1
1
1
1
1
1
1
1
2
1
2
4
8
12
14
21
16
21
26
21
3
5
9
13
16
24
17
24
28
24
Cat ref.
Opaque Door
Cat ref.
Transp. door
VF104PT
VF108PT
VF112PT
VF118PT
VF212PT
VF218PT
VF312PT
VF318PT
VF412PT
VF418PT
VF104TT
VF108TT
VF112TT
VF118TT
VF212TT
VF218TT
VF312TT
VF318TT
VF412TT
VF418TT
golf enclosure with 100A brass terminals
VF318TT
VF412TT
22
Description
Busbar
Cat ref.
Opaque Door
Cat ref.
Transp. door
1 row 12 I
1 row 18 I
2 row 24 I
2 row 36 I
3 row 36 I
3 row 54 I
4 row 48 I
4 row 72 I
1 x 12 pole
1 x 18 pole
2 x 12 pole
2 x 18 pole
3 x 12 pole
3 x 18 pole
4 x 12 pole
4 x 18 pole
VF112PTH
VF118PTH
VF212PTH
VF218PTH
VF312PTH
VF318PTH
VF412PTH
VF418PTH
VF112TTH
VF118TTH
VF212TTH
VF218TTH
VF312TTH
VF318TTH
VF412TTH
VF418TTH
golf VF series enclosures
Flush mounted with link terminals
Flush mounted distribution
boxes from 1 to 4 rows, from
4 to 72 modules, supplied
with opaque or transparent
door for devices up to
70mm installation depth.
Door can be fitted on right or
left, optional lock and keys.
Door opens up to 180º.
Wall box and cover are
symmetrical for removable
cable entry slider. Cable
entries for cable and conduit.
VF Components:
- Earth & neutral terminals
- Pole fillers
- Patented marking system
in enclosures >36 I
- Cable management clips
in enclosures >36 I
- Transport protection film
- Busbar supplied with
some references
golf enclosure with
Description
VF318TT
1 row 12 I
1 row 18 I
2 row 24 I
2 row 36 I
3 row 36 I
3 row 54 I
4 row 48 I
4 row 72 I
Technical data:
- IP rating:
IP30 without door
IP40 with door
IK07
- Isolation Class II
- White colour RAL 9010
- Rated current:
for devices up to 63A
- Rated insulation voltage:
400V AC/50Hz
Standard: all products
conform to Australian and
international standards.
All products conform to the
RoHS and WEEE directives.
link terminals
Busbar
1 x 12 pole
1 x 18 pole
2 x 12 pole
2 x 18 pole
3 x 12 pole
3 x 18 pole
4 x 12 pole
4 x 18 pole
link terminal
25mm2
4mm2
3
4
4
7
7
10
10
15
15
20
20
29
29
42
36
55
Cat ref.
Opaque Door
Cat ref.
Transp. door
VF112PTQ
VF118PTQ
VF212PTQ
VF218PTQ
VF312PTQ
VF318PTQ
VF412PTQ
VF418PTQ
VF112TTQ
VF118TTQ
VF212TTQ
VF218TTQ
VF312TTQ
VF318TTQ
VF412TTQ
VF418TTQ
23
golf enclosures
Accessories
golf enclosure accessories
Includes an extensive range,
from cable retainers to hollow
wall anchors, keys, locks and
doors, every single feature is
conceived to save time and
increase simplicity of mounting.
Opaque Doors
VZ610N
To suit
Pack
Cat ref.
VF/VS104
VF/VS108
VF/VS112
VF/VS212
VF/VS312
VF/VS412
VF/VS118
VF/VS218
VF/VS318
VF/VS418
1
1
1
1
1
1
1
1
1
1
VZ601N
VZ602N
VZ603N
VZ604N
VZ605N
VZ606N
VZ607N
VZ608N
VZ609N
VZ610N
Transparent Doors (polycarbonate)
VZ630N
To suit
Pack
Cat ref.
VF/VS104
VF/VS108
VF/VS112
VF/VS212
VF/VS312
VF/VS412
VF/VS118
VF/VS218
VF/VS318
VF/VS418
1
1
1
1
1
1
1
1
1
1
VZ621N
VZ622N
VZ623N
VZ624N
VZ625N
VZ626N
VZ627N
VZ628N
VZ629N
VZ630N
Earthed metal back plate
To suit
Pack
Cat ref.
VF108
VF112
VF118
VF212
VF218
VF312 (available early 2015)
VF318
VF412
VF418
1
1
1
1
1
1
1
1
1
VF108BP
VF112BP
VF118BP
VF212BP
VF218BP
VF312BP
VF318BP
VF412BP
VF418BP
Key Lock
VZ794N
24
Description
Pack
Cat ref.
Supplied with 2 keys
1
VZ794N
golf enclosures
Home networking modules
Our home networking enclosures
allow you to combine mains
distribution boards with
home networking or as a
stand alone enclosure.
Features:
- True flush mounting base on
18 pole wide enclosures
- Steel mounting pan
- Vented door
- DIN rail (12 mods wide)
- Vertical Double GPO
- Slider (incorporates GPO
mounting block).
NOTE: Joining double slider
for use with 18 module wide
flush enclosures only.
Home networking enclosures
VF218PZD
Description
Size in mm
Cat ref.
Flush enclosure with
- Vented door
- Double vertical GPO
- Mounting pan
- DIN
- Single slider
460w x 418h
460w x 543h
460w x 688h
VF218PZD
VF318PZD
VF418PZD
Extension box
VF218VZE
Description
Size in mm
Cat ref.
218 sized flush enclosure with:
- Vented door
- Mounting pan
- Double Vertical GPO
- DIN
- Double slider for combining with any VFX18 golf enclosure
460w x 418h
VF218PZE
Sliders
VZ850N
Description
Suits
Cat ref.
Double slider (combines two enclosures)
Single slider
VFX18
VFX18
VZ850N
VZ852N
25
golf enclosures
Home networking accessories
The components that come
supplied as standard within
our media enclosures are
also available separately.
Additional patching modules in
Cat6 & Cat6 shielded, F-type
modules, telephone splitters
and other accessories are
also available separately.
The TN003S & TN002S Cat6
UTP & STP patch modules
provide a toolless wiring system
(no punch down required)
with positive cable retention
ensuring every cable remains
in place and stays connected.
The 2 in 8 out telephone splitter
can be bridged to give a 1 in 8
out configuration if required.
Accessories
Description
Characteristics
Cat ref.
Connectors
RJ45 Cat 6 STP patch modules
RJ45 Cat 6 UTP patch modules
Coax F/F module
1 input / 4 output
2 input / 8 output
12 pole length
RJ45 Cat 6 patch cable 0.3m
RJ45 Cat 6 patch cable 0.5m
RJ45 Cat 6 patch cable 1m
to suit VF/VS218 with vents - opaque
to suit VF/VS318 with vents - opaque
to suit VF/VS418 with vents - opaque
for VZ850N
for Cog rail mount type devices
TN002S
TN003S
TN010S
TN131
TN111
VZ854N
TN733B
TN735B
TN740B
VZ855N
VZ856N
VZ857N
VZ851N
VZ853N
VZ794N
Telephone splitter
TN010S
TN002S
Din rail
Patch cables
Doors
TN131
VZ853N
TN735B
26
Segregation Plate
Cog mounting plate
Key Lock
Isolating switches
Description
For use as a switch isolator in
all types of circuits. As defined
in AS/NZS3000-2007, clause
2.3.3.2, domestic installations
require no more than one main
switch for each metered supply.
Technical data
AC 22B duty specification
(mixed resistive and inductive
loads. Not motors)
Connection capacity
- In: 40, 63, 80A
-25mm2 rigid cables
-16mm2 flexible cables
- In: 63A & 100A
-50mm2 rigid cables
-35mm2 flexible cables
Single pole Isolating switches
Characteristics
Width
Cat ref
1
1
1
1
1
1
1
1
SBR140
SBR163
SBR180
SBR190
x
x
x
x
40A 250V~
63A 250V~
80A 250V~
100A 250V~
mod
mod
mod
mod
SBR163
Double pole Isolating switches
Characteristics
Width
Cat ref
2
2
2
2
2
2
2
2
SBR240
SBR263
SBR280
SBR290
x
x
x
x
40A 250V~
63A 250V~
80A 250V~
100A 250V~
mod
mod
mod
mod
SBR263
Triple pole Isolating switches
Characteristics
Width
Cat ref
3
3
3
3
3
3
3
3
3
3
SBR340
SBR363
SBR380
SBR390
SBR399
x
x
x
x
x
40A 400V~
63A 400V~
80A 400V~
100A 400V~
125A 400V~
mod
mod
mod
mod
mod
SBR399
Four pole Isolating switches
Characteristics
N 4 x 63A 400V~ neutral right
4 x 100A 400V~ neutral right
Width
Cat ref
4 mod
4 mod
SBR463
SBR490
SBR490
27
MCB’s - 6kA ‘C’ curve
Residential
Technical data
- Complies with
AS/NZS 60898
- Tripping characteristics:
magnetic level is set at
5 - 10 x In(C - curve)
- Breaking capacity: 6000A
- Voltage rating: 240/415V AC
- Current rating: 6 to 63A
- Mechanical life: 20,000
operations
- Bi-connect allowing two
connection points
Current Rating (A)
Width
Pack Qty
Cat ref
6
10
13
16
20
25
32
40
50
63
63
1
1
1
1
1
1
1
1
1
1
1
12
12
12
12
12
12
12
12
12
12
12
MSN106
MSN110
MSN113
MSN116
MSN120
MSN125
MSN132
MSN140
MSN150
MSN163
MSN163R
Current Rating (A)
Width
Pack Qty
Cat ref
6
10
16
20
25
32
40
50
63
2
2
2
2
2
2
2
2
2
6
6
6
6
6
6
6
6
6
MSN206
MSN210
MSN216
MSN220
MSN225
MSN232
MSN240
MSN250
MSN263
Current Rating (A)
Width
Pack Qty
Cat ref
6
10
16
20
25
32
40
50
63
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
MSN306
MSN310
MSN316
MSN320
MSN325
MSN332
MSN340
MSN350
MSN363
Description
Protection and control of
circuits against overloads and
short-circuits in residential
installations.
Connection capacity
-25mm2 rigid
-16mm2 flexible
Single pole
MSN120
MSN163R
mod
mod
mod
mod
mod
mod
mod
mod
mod
mod
mod
Double pole
MSN220
mod
mod
mod
mod
mod
mod
mod
mod
mod
Triple pole
MSN320
28
mod
mod
mod
mod
mod
mod
mod
mod
mod
RCBO’s - type A, ‘C’ curve
Residential
Description
RCBO’s are compact
combination devices which
provide MCB overcurrent
protection & earth leakage
protection. The Type A devices,
with line neutral switched, are
available with various current
ratings ranging from 10A - 40A.
Type A devices are designed
with intrinsic features that can
detect AC as well as pulsating
DC residual currents.
The type A device filters out
interference from modern
day appliances such as TV’s
washing machines and LED
lighting, that can potentially
prevent the device from
operating accurately.
Features
- Earth fault indication window
- Trip free mechanisms
1 mod connection capacity
-10mm2 flexible
-16mm2 rigid
Specifically designed for
DIN rail enclosures
Accessories
- Toggle locking device
2 mod connection capacity
-16mm2 flexible
-25mm2 rigid
1 module RCBO 6ka Type A
Residual current Irn
Current rating (A)
Width
Cat ref
30mA
30mA
30mA
30mA
30mA
10A
13A
16A
20A
25A
1
1
1
1
1
ADC310T
ADC313T
ADC316T
ADC320T
ADC325T
Residual current Irn
Current rating (A)
Width
Cat ref
10mA
10mA
10mA
30mA
30mA
30mA
30mA
30mA
30mA
30mA
10A
13A
16A
10A
13A
16A
20A
25A
32A
40A
2
2
2
2
2
2
2
2
2
2
ACA910T
ACA913T
ACA916T
ADA910T
ADA913T
ADA916T
ADA920T
ADA925T
ADA932T
ADA940T
mod
mod
mod
mod
mod
ADC320T
2 module RCBO 6ka Type A
Ph
ADA910T
N
mod
mod
mod
mod
mod
mod
mod
mod
mod
mod
29
RCCB’s
Safety switches
Description
The safety switch is designed
to open a circuit automatically
in the case of a fault between
phase and earth and/or neutral
and earth, greater than or equal
to rated tripping current.
Use in domestic, commercial
or industrial installations.
Features
- Conforms with IEC 60898-1,
60947-2 and AS/NZS 61008.1
- Voltage rating, 230/415V~
- Positive contact
indication windows
- Earth fault indication window
- Trip free mechanisms
Residential
Double pole
1
Connection capacity
2
-25mm - Rigid
(50mm2 for 80A,100A)
2
-16mm - Flexible
(35mm2 for 80A, 100A)
Accessories
- Auxiliary & alarm contacts
- Toggle locking device
- Neutral links
- Shunt trip
- Undervoltage release
Description
Residual current Irn
Current rating (A)
Width
Cat ref.
Type A
30mA
30mA
30mA
30mA
30mA
25A
40A
63A
80A
100A
2
2
2
2
2
CDA225T
CDA240T
CDA263T
CD280T
CD284T
Residual current Irn
Current rating (A)
Width
Cat ref.
25A
40A
63A
80A
100A
4
4
4
4
4
CDA425T
CDA440T
CDA463T
CD481T
CD485T
3 N
T
Type AC
2
mod
mod
mod
mod
mod
4 N
CDA240T
Description
Residential
Four pole
L1
L2
L3
1
3
5
Type A
N
L1 L2
7 N
2
L1
L1
L2
L3
1
3
5
N
1
6
L3
8 N
N
L3
3
5
2
4
L1 L2
6
L3
7
N
T
T
2
L1
30
4
L2
L1 L2
7 N
4
L2
6
L3
8 N
N
3
5
2
4
L1 L2
6
L3
T
T
CDA440T
1
L3
8 N
7
30mA
30mA
N
30mA
30mA
30mA
8 N
mod
mod
mod
mod
mod
Insulated busbars and connectors
Description
A range of connection devices
to simplify installation of
modular devices such as
MCB’s, RCD’s etc...
KDN180A
Insulated busbars - Fork type
Characteristics
Width
Cat ref
1
1
2
3
3
12
18
12
12
18
KDN180A
KDN180G
KDN280A
KDN380A
KDN380G
phase
phase
phase
phase
phase
80A
80A
80A
80A
80A
mod
mod
mod
mod
mod
Insulated busbars - Tongue type
KB181GI
Characteristics
Width
Cat ref
6 tongue
9 tongue
12 mod
18 mod
KB181A1
KB181G1
Insulated caps
KZ059
Description
Characteristics
Cat ref
Busbar end caps
Busbar end caps
Fork caps - yellow
Suits KDN1xx & KB181xx
Suits KDN2XX/KDN3XX
KB181A1
KB181G1
KZ059
Cable Connectors
Characteristics
Tongue
Tongue
Tongue
Tongue
Tongue
KRN163
type
type
type
type
type
Cat ref
connection
connection
connection
connection
connection
from
from
from
from
from
top for cables: 25mm
top for cables: 2 x 16mm
side for cables: 35mm2
side of cables: 35mm2 with longer tongue
side of cables: 35mm2 with longer insulated tongue
Fork type connection from side for cables: 25mm2
DIN mounted
KF81A
KF82A
KF83A
KF83D
KF83F
KF84A
KRN163
Other accessories
Description
Characteristics
Cat ref
RCD neutral links
Cable adaptor
3 tunnel link for fitting to RCD’s
35mm2 to suit golf enclosure
KM03A
KM035
KM03A
31
F
golf VS/VF enclosures
Technical summary
Cable entries
125mm
H5=125mmF
H
1 row 4 z
2 row 8 z
1 row 12 z
2 row 12 z
3 row 12 z
4 row 12 z
1 row 18 z
2 row 18 z
3 row 18 z
4 row 18 z
1 row 22 z
Wall fixation
E
F
101
68
174
68
222
136
222
261
222
386
222
491
330
136
330
261
330
386
330
491
402
136
G
58
58
58
58
58
78
58
58
58
78
58
E
E
A
A
A
72mm
F
F
E
VF104...
VF108...
VF112...
VF212...
VF412...
VF118...
VF218...
VF318...
VF418...
VF122...
46
46
Flush Ref
1 row 4 z
2 row 8 z
1 row 12 z
2 row 12 z
4 row 12 z
1 row 18 z
2 row 18 z
3 row 18 z
4 row 18 z
1 row 22 z
Wall Cut Out
E
F
170
189
242
189
318
257
318
382
318
652
426
257
426
382
426
507
426
652
498
257
For the wall cut out, these dimensions are minimal.
Depth must always be 72mm min.
E
A
Cutout for combined boards utilising double slider
46
26mm
26mm
72mm
F
When connecting 2 x VFX18 enclosures with a double slider, an additional 38mm must be added
to the total cutout height of the boards.
e.g. VF118PT joining with a VF218PZD = 257mm + 382mm + 38mm.
Total height for the cutout = 677mm.
Width remains consistent at 460mm.
NOTE: Joining double slider for use with 18 module wide flush enclosures only.
38mm
26mm
E
32
Dimension
A
H
204
225
275
225
352
293
352
418
352
688
460
293
460
418
460
543
460
688
532
293
Subject to technical changes
G
72mm
F
A
H5=125mm
H5=125mm
G
VS104...
VS108...
VS112...
VS212...
VS312...
VS412...
VS118...
VS218...
VS318...
VS418...
VS122...
Dimension
A
H
138
184
210
184
282
252
282
377
282
500
282
647
390
252
390
377
390
500
390
647
462
252
F
Surface Ref
G
99
E
F
A
G
top/bottom
- One side of the surface enclosure is designed for use of trunking and knock outs. The other side of the enclosure has dimples located for the various sizes of conduit entries, 20mm, 25mm, 32mm and 40mm. The enclosure is symmetrical through 180º.
- For flush enclosures, Precut with diameters 20, 25, 32 and 40mm, the wall box is 180º rotatable, to provide slider position on top or bottom.
A
Technical summary
MSNxxx
ADCxxxT
ADAxxxT
CDAxxxT
1P, 2P & 3P MCBs
1 mod. RCBOs
2 mod. RCBOs
2P & 4P RCCBs
Rated current (In):
6A to 63A
10A to 32A
10A to 40A (30mA) ;
10A to 16A (10mA)
25A to 63A
Rated voltage (Un)
230V to 240V (1P & 2P),
400V to 415V (3P)
240V
240V
240V
Curve Type:
C
C
C
-
Rated residual operating
current (I∆n)
-
30mA
10mA, 30mA
30mA
Operating characteristic:
-
Type A
Type A
Type A
Rated Frequency:
50/60Hz
50Hz
50Hz
50Hz
Rated short-circuit capacity
(Icn):
6000A
6000A
6000A
-
Residual making and breaking
capacity
4500A
4500A
1500A
IP rating:
IP2x terminals
IP2x terminals
IP2x terminals
IP2x terminals
Standard:
AS/NZS 60898
AS/NZS 61009-1
AS/NZS 61009-1
AS/NZS 61009-1
Approval:
RCM logo
RCM logo
RCM logo
RCM logo
Maximum service voltage:
60V
253V
240V
240V (2P) - 415V (4P)
Minimum service voltage:
250/440V
85V
127V
127V (2P) - 240V (4P)
Technology
-
Line voltage
dependent tripping
Line non-voltage
dependent tripping
Line non-voltage
dependent tripping
Power supply (line side):
Feed either top
or bottom
Bottom
Feed either top
or bottom
Feed either top
or bottom
Isolation application:
Yes (IEC 60898)
Yes (IEC 61009-1)
Yes (IEC 61009-1)
Yes (IEC 61008-1)
Operating temperature:
-25°C to + 60°C
- 5°C to + 55 °C
-25°C to + 40°C
-25°C to + 40°C
Storage temperature:
-25°C to + 80°C
- 25°C to + 80 °C
-55°C to + 70°C
-55°C to + 70°C
Terminal capacity (top):
Rigid or stranded
conductor:
Rigid or stranded
conductor:
Rigid or stranded
conductor:
Rigid or stranded
conductor:
1 mm² to 25 mm²
1 mm² to 16 mm²
(or 2x 6 mm²)
1 mm² to 25 mm²
1 mm² to 25 mm²
Rigid or stranded
conductor:
Rigid or stranded
conductor:
Rigid or stranded
conductor:
Rigid or stranded
conductor:
1 mm² to 25 mm²
1 mm² to 16 mm²
1 mm² to 25 mm²
1 mm² to 25 mm²
Terminal torque (top/bottom):
2.5 Nm nominal with size
2 pozidrive screw head
and 6mm slot
2.3 Nm nominal with size
2 pozidrive screw head
and 6mm slot
2 Nm nominal with size 2 2.8 Nm nominal with size
pozidrive screw head and 2 pozidrive screw head
6mm slot
and 6mm slot
Busbar system:
Yes, fork
Yes, fork
Yes, fork
Yes, fork
Neutral lead length:
NA
1000 mm
NA
NA
Terminal capacity (bottom):
Subject to technical changes
33
make the switch
in your beautiful home
Make the connection
Whether connecting your home theatre
components, speakers, amplifier, Foxtel,
digital TV or simply a phone line, we have
the mechanisms to do the job. Available in
either horizontal or vertical configurations,
with our patented RotoLoc® mechanisms,
you’ll never experience ‘pushing your
cable plug into the wall cavity’ again.
A wider range than you thought?
Worth a closer look...
Hager Electro Pty Ltd
1/170 Power Street
Glendenning NSW 2761
www.hagerelectro.com.au
Nationwide sales
Ph 1300 850 253
Fx 1300 424 372
Email: [email protected]
State offices in:
New South Wales
South East Queensland
North Queensland
Victoria
South Australia
Western Australia
Distributors in:
Tasmania
Northern Territory
DISCLAIMER: Whilst every effort has been made to ensure the reliability of the information is correct
at time of publication, Hager cannot guarantee the accuracy of all of the information contained herein.
Changes/updates brought to the attention of Hager, once verified, will be corrected in future editions.
0236PPRDS14

Similar documents

×