INSTANT MEASUREMENT

Document technical information

Format pdf
Size 4.0 MB
First found Nov 13, 2015

Document content analysis

Language
English
Type
not defined
Concepts
no text concepts found

Organizations

Places

Transcript

NEW
Image Dimension Measurement System
IM-6120 Series
Wide-field Model
Wide-field Model
Instant
Measurement
IM Series Image Dimension
Measurement System
200 mm
Wide-field Model
2
Faster and
More PRECISE
Optical
comparator
Just Place and Press
A Completely New Way of Inspecting Parts
Image dimension
measurement system
Measuring
microscope
How can functionality be improved while retaining
the advantages of conventional measurement systems?
After facing this question squarely and thoroughly,
we have reached an answer:
Combine revolutionary technology with a cutting edge
user interface.
Optical CMM
By providing both overwhelming measurement speed
and high measurement accuracy, the IM Series
image dimension measurement system changes your
measurement operations dramatically.
Comparison with various measurement systems
Hand caliper/
micrometer
GD&T and Profile
Measurement
System
Measurement
time
Individual
differences
Optical comparator
×
×
✓
×
Measuring microscope
×
×
✓
×
User friendliness Data management
Optical CMM
×
✓
×
✓
GD&T and Profile
Measurement System
×
✓
×
✓
Hand caliper
✓
×
✓
×
IM Series
✓
✓
✓
✓
3
Four Advantages
Drastically Reduced
Measurement Time
Conventional
Eliminating
Operator Error
Conventional
Manual part positioning and focus adjustment are
Measurement results vary depending on habits and skill
required. The more the measurement points,
levels of individual operators such as a measurement point
the longer the time required for measurement.
selection, part alignment procedure, and focus position.
Example:
When 300 or more seconds are required to measure
10 points with an optical comparator
? mm
Different results among different operators...
Operator A
Operator B
Operator C
300 seconds or more
Optical
comparator
Positioning time
Focus adjustment time
Measurement time
78.4 mm
IM Series
<
78.6 mm
<
78.8 mm
IM Series
No individual differences!
5 seconds or less
IM Series
Operator A
Operator C
No need for focus adjustment and positioning
78.6 mm
=
78.6 mm
=
78.6 mm
Measurement requires only placing a target
The location and orientation of a target are
on the stage and pressing the measurement
automatically adjusted and measurement is
start button. This simple operation enables 99
performed using the specified points. Manual
features to be measured in seconds, leading to
operations, which used to cause measurement
significant reduction in time required for dimension
differences are not required such as measurement
measurement.
point selection, edge alignment, and focus
adjustment.
4
Operator B
Easy Data
Management
Easy Operation
for Everyone
Conventional
Conventional
Data management requires time and effort such as
The higher the magnification, the narrower the field
recording results on paper and entering data into
of view, which decreases operation efficiency and
a PC.
user friendliness.
1
MEASUREMENT COMPLETE
2
FILLOUT AN INSPECTION RECORD
3
INPUT DATA TO A PC
4
PROCESS WITH SPREADSHEET SOFTWARE
5
PREPARE AN ANALYSIS/INSPECTION REPORT
IM Series
1
2
Partial view of a target,
requiring point-by-point
measurement
IM Series
MEASUREMENT COMPLETE
Industry first
Captures the entire
image of a target and
measures
simultaneously
PREPARE AN ANALYSIS/
INSPECTION REPORT
Inspection report
Measurement results are saved automatically in
The IM Series enables you to set measurement
the controller. Manual operations such as statistics
points while checking the entire image of a target.
management of measurement results and data
In addition, measurement points can be selected
transfer to a PC can also be done easily.
simply with the mouse. This ensures simple
operation for everyone.
5
Optical Technologies for Achieving
“Place-and-Press” Measurement
6
Clear focus regardless of height differences
KEYENCE’s specifically designed lens
provides a super wide field of view.
Target viewed from front
IM Series
Zoom lens
Coupled with the Auto-Focus
capability, the IM Series ensures the
part is always in focus regardless of
height differences. This allows for
optimal accuracy at all times without
worrying about setup.
The image is out of focus due to height differences
The image is in focus regardless of height
differences
Apparent feature size not affected by height differences
A telecentric lens maintains a constant
Zoom lens
image size regardless of height
Target viewed
from upper right
IM Series
differences of a target. This allows
accurate measurement of targets with
uneven surfaces.
Less distortion even along circumference
A lens with a low distortion even for
the area along the outer edge of the
Zoom lens
IM Series
field of view. Targets can be measured
without concerns of their placement.
The area along the outer edge is shown distorted
The image is less distorted throughout the field
of view
7
High-precision Stage for Achieving
“Place-and-Press” Measurement
8
Achieving twice* the measurement range as conventional systems
A newly developed high-precision
stage enables multiple images to be
Image binding
stitched so that you can measure an
entire target simultaneously even
when it is not contained in the same
+
+
field of view.
* Comparison with our IM-6015/6025 Series
Measurement and setup possible with the entire target in view
Everyone can operate this system
IM Series
Conventional method
easily because not only the entire
target can be measured simultaneously
but also measurement points can be
specified while checking the entire
image.
Partial view of a target
Stage technologies that support measurement
High-precision stage
with high linearity
IM Series
Without adjustment
Turning force applied
High linearity is achieved by using
Range of FOV
High linearity
Range of FOV
Measured dimension
precision cross roller bearings for high
accuracy and increased rigidity.
Actual dimension
Stage movement
Stage movement
Smaller difference
between actual and
measured dimensions
Specifically designed,
high-precision linear scale
A specifically designed linear scale
is mounted to achieve dimension
measurement accuracy in micron
increments.
Linear scale
module
9
Measurement Time Drastically Reduced through Unparalleled Speed
Just Place and Press to Complete Dimension Measurement
MEASUREMENT COMPLETE
10
Industry first
Pattern search for automatic location and orientation correction
The location and orientation of the
target placed on the measurement
stage are automatically detected and
measured based on the recorded
shape of the target. There is no need
for positioning of the target or
preparation of a jig at the beginning of
measurement.
Industry first
Simultaneous measurement of 99 features by capturing an entire part
This is a completely new
measurement system which measures
by capturing the entire image of
a target within the field of view.
Measurement is completed in a short
time because all features are
measured after the entire image is
captured.
Industry first
Batch measurement for further reduction in measurement time
The dimensions of all targets on the
stage are measured simultaneously.
Even when the targets are placed
randomly, their locations and
orientations are detected and
measured automatically.
11
61.200 mm
61.200 mm
61.200 mm
61.200 mm
61.200 mm
Same Results no Matter who Carried Out the Measurement
Latest Image Processing Technology Eliminates Individual Differences
61.200 mm
61.200 mm
61.200 mm
61.200 mm
61.200 mm
12
Sub-pixel processing for measurement down to
one hundredth or less of one pixel
Sub-pixel processing allows one pixel
on the light receiving element to
One pixel of the light
receiving element
essentially be processed as 100 or
more pixels. This allows for
high-resolution measurement even
with a wider field of view.
Without sub-pixel processing
With sub-pixel processing
The target is measured by one pixel of the
light receiving element.
The target is measured by one hundredth or
less of a pixel of the light receiving element.
One pixel is
divided into
100 or more
squares
A line or circle is recognised using 100 or more points*
The shape of a line or circle used for
measurement is recognised by the
least square fit algorithm using
approximately 100 points detected
automatically. Using many points
ensures stable measurement.
* The exact number of points is user adjustable
for optimal detection.
About 100 points are detected automatically.
The shape is recognised by the least square method
using the detected points.
Eliminating discrepancies in results caused by burrs and chips
During the extraction of a line or circle,
the system eliminates the influence of
burrs or chips by ignoring points at
abnormal locations in comparison with
other points. It is also possible to set
the system to interrupt measurement
when burrs or chips are found.
Options for processing abnormal points,
burrs, and chips
Abnormal points (red points) are ignored during shape
recognition.
13
Data Management
as You Like It
This Single System Covers All from
Data Management to Analysis
14
Automatic calculation of major statistical values.
Group extraction is also easy.
Critical statistical values required for
inspection reports are automatically
calculated and displayed, including
maximum, minimum, average, σ, 3σ
and Cpk. You can also set various
conditions for group extraction for
Groups can be extracted on various
conditions.
statistical, analysis, and inspection
records.
Critical statistical values required for inspection reports are provided
by default.
Trend graph/histogram functions for on-site analysis of
product trends and variations
The trend graph/histogram function
allows on site analysis of production
trends and variations. Quick feedback
helps quality management prevent
production of defective parts.
The trend graph shows tendencies of a product at a
quick glance.
Histogram settings can be adjusted as required.
Data can be used easily in reports or spreadsheet software.
Inspection records and analysis
reports can be prepared with the press
of a button. No additional work is
required such as data transcription or
input to a PC. It is also easy to import
measurement data to spreadsheet
software for processing.
Inspection records and reports can be prepared
easily.
Measurement data can also be used easily on
spreadsheet software.
15
Easy Operation for Everyone
The higher the magnification, the narrower the field of view, which decreases operation efficiency and
user friendliness. The IM Series enables you to set measurement points while checking the entire image
of a target. In addition, measurement points can be selected simply with the mouse. This ensures simple
operation for everyone.
Just click the points to be measured with the mouse
To set up feature inspections, just
select the desired tool from the menu
and roughly specify the measurement
points on the screen with the mouse.
Since the entire image of a target is
displayed, you can set details
intuitively through simple mouse
operations.
Select a desired measurement type from the menu.
Roughly specify the measurement points with the
mouse.
NEW
Automatic focus adjustment of targets with height differences
The focus is also adjusted
automatically according to the shape
Only upper image is
in focus
of the target. The system is even
capable of focusing on different
surfaces on the same part for the
same measurement, allowing greater
flexibility.
Only lower image
is in focus
Even when the target is out of focus due to
height differences...
The focus is automatically adjusted for
measurement
Easy measurement using centre lines or virtual points
Various options are available for
facilitating the measurement using
centre lines or virtual points for which
complicated setup was required.
Moreover, a special menu is available
for measuring small rounded corners,
curved surfaces, and geometric
tolerances such as position or
concentricity.
16
Various options including a midline
and intersection.
Various options from basic measurement to geometric dimensioning and
tolerancing
Industry first
Automatic element extraction function
Just specify the points along the
perimeter of the target, and the
element required for measurement
such as a “line”, “circle” or “arc” is
automatically extracted. All you have to
do now is select an option for
measurement and click the extracted
element.
Highlight the target area.
Any lines, circles, or arcs are extracted automatically.
Just surround the thread section
Simple measurement also for outer, effective, and root
diameters
NEW
Thread tool
A special menu is also available for
thread measurement. Dimensions
required for threading such as outer
and effective diameters can be
measured easily just by surrounding
where to measure with the mouse.
Profile comparison function & perimeter measurement
The profile tolerance (difference from
the reference dimension) or perimeter
of a target can be measured.
The reference dimension for the profile
tolerance measurement can be
created from CAD data*.
* Optional software required.
Perimeter measurement (sealing material)
Profile tolerance measurement (moulding)
NEW
Consolidate measurement settings
Separate measurement settings can
be bound to one data set. It is also
possible to output one collective result
after successive measurements.
Binding multiple measurement settings
Viewable as one result
17
Networking Function & Software
The IM Series is provided with network communication function and various software to improve its
usability further after introduction.
This facilitates communication between field and office as well as onshore and offshore factories.
Central data management
A LAN connection allows you to easily obtain
Remote
factory
measurement data or setting files for IM Series
units located in remote locations. You can also
send the setting files created on a PC or
one IM Series unit to another IM Series unit.
Setting file
PC
Server
Setting file
Internal LAN
Managing data centrally on a server reduces
the risk of data loss.
Measurement data
Statistics/analysis viewer
With the statistics/analysis viewer, the results of
measurement with the IM Series can be checked
also on a PC. This viewer can also be used for
aggregating operations such as statistics/analysis
and report preparation.
Statistics/analysis viewer
Statistical data
18
Measurement data
CAD import module
[Optional: IM-H1C]
Even when a target is not at hand,
an IM setting file can be created
based on CAD data.
* Measurement setup editor required
separately.
CAD import module
Measurement setting data
Measurement setup editor
[Optional: IM-H1EE]
The setup editor lets you edit or set up
new setting files all from your PC.
Measurement setup editor
Measurement setup
NEW
Data transfer software
[Optional: IM-H1T]
The results can be exported directly
from the IM Series to your PC in a
user-defined format.
❙ Operating system environment
Applicable OS
Windows XP Professional/Home Edition SP3 or later (32-bit version),
Windows Vista Ultimate/Business/Home Premium/Home Basic SP2 or later (32-bit version),
Windows 7 Ultimate/Professional/Home Premium SP1 (32/64-bit version), preinstalled version
CPU
Intel Core 2 Duo 1.6 GHz or higher
Memory capacity
2 GB or more
HDD free space
2 GB or more
Display colour
32 bits or more
19
Performance and Reliability for Field Use
Traceability system diagram
The reference scales used for
manufacturing, inspection, and
calibration conform to the reference
scale of JCSS accredited calibration
laboratories to establish traceability
back to the national standard.
International standard
JCSS accredited calibration laboratory
Secondary standard
Common standard
Measuring instrument to be calibrated
National Metrology Institute of Japan (NMIJ) of National
Institute of Advanced Industrial Science and Technology
Reference scale
Precision coordinate measuring instrument
Reference scale
IM Series image dimension measurement system
Highly rigid body and temperature sensor ensures
practical installation anywhere.
The highly rigid body and built-in
Built-in
temperature sensor
temperature sensor have enabled
“installation anywhere”. Deformation
is limited as to not affect measurement
and temperature compensation
ensures accurate measurement in
the field.
Frame strength analysis diagram
Temperature sensor ensures more stable measurement.
Space-saving design small footprint
In addition to the compact body,
the built-in monitor saves significant
space in the installation process. It can
be installed anywhere. These
important features allow you to take
your lab to the production line for
immediate part feedback.
Small
footprint
Projector
20
Image Measure IM Series
Measuring microscope
Support System that Ensures Secure Operation after Introduction
Training tools
To enable you to start using this system immediately after
introduction, various training tools are available, including Easy
Setup Manual and Setup Training Cards, so that you can easily
master how to operate the system.
Settings Dictionary - Search by Purpose
Your First choice in Dimension Measurement
IM-6000 Image Dimension Measurement System
IM-6500 Image Dimension Measuring System
QUICK SETUP MANUAL
QUICK SETUP MANUAL II
Quality support only possible with direct sales system
Our comprehensive after-sales service and support through
technical sales representatives with extensive expertise and
[General manufacturer]
knowledge can only be achieved by our direct sales system from
the manufacturer where no agents or distributors intervene. It is
ensured that you can consult us immediately whenever you want.
Customer
Vendor
Agent
Manufacturer
[KEYENCE]
Direct sales
Customer
KEYENCE
21
Global Support System
Comprehensive Coverage All Over the World
United Kingdom
United States
China
Germany
Italy
India
Japan
Taiwan
Belgium
Philippines
Thailand
France
Vietnam
Malaysia
Singapore
22
Indonesia
Support system
Our technical sales staff respond promptly to your requests.
We offer not only technical support but also various advices on
[Direct sales from manufacturer]
export, import, and customs. Even overseas, we maintain our
direct sales system from the manufacturer so that you can
receive consistent support from selection to startup of a system.
Consistent support by technical sales representatives
Selection
Introduction
After-sales
service
Support in various languages
Not only operation screens on the main unit but also other
materials such as the instruction manual are available in various
[Supported languages]
languages. After introduction into overseas production sites, local
staff can also use this system smoothly.
English
German
French
Italian
Simplified
Chinese
Traditional
Chinese
Thai
Korean
Japanese
Instant delivery system even for overseas
A wide variety of products are stocked at distribution sites in
each country so that they can be delivered promptly on the day
we receive order. You do not need to worry about if it may take
considerable effort and time to obtain a product from an overseas
factory.
23
Two Types of Illumination for a Wide Range of Measurements
Backlighting
Ring
illumination
24
A high intensity green LED light is mounted at the bottom of the head unit. Uniform, parallel
light has been achieved through KEYENCE’s accumulated expertise in lens development.
Optimised illumination ensures a wide field of view and stable measurement of targets even
with significant height differences.
Torsion spring
Lead frame
Gear
Stamped part
A high intensity white LED ring light surrounds the image pickup lens.
The light is divided into four parts along the circumference. These can be turned on/off
individually. These settings are then retained as part of the inspection routine, allowing each
individual feature to have individually optimised lighting settings.
Plastic cap
Moulded connector
Ceramic capacitor
Keypad
Optional Illumination
Coaxial
illumination
With this illumination unit, the light emitted from the LED light source mounted on the side is
illuminated straight downward through a half mirror. This is effective for measurement of
slanting surfaces such as tapered sections or glossy targets.
CA-DXW7
Rivet (ring illumination)
Rivet (coaxial illumination)
CA-DXW5A
Plastic moulding (ring illumination)
Plastic moulding (coaxial illumination)
Low-angle
illumination
CA-DLR12
Using a LED light source to illuminate the target from a low angle, it is possible to effectively
light targets with uneven surfaces or diffuse edges.
Plastic cap (ring illumination)
Plastic cap (low-angle illumination)
25
System Configuration
Head
Controller
IM-6120
Wide-field model
PC software
(shipped together with the main unit)
IM-H1VE
Statistics/
analysis
viewer
IM-6600E
Software (optional)
IM-H1EE
Measurement
setup editor
IM-H1C
CAD import
module
IM-H1T
Data
transfer
software
Options (illumination)
CA-DXW7
Coaxial illumination
(50 x 50 mm)
CA-DXW5A
Coaxial illumination
(35 x 35 mm)
CA-DLR12
Low-angle
illumination
OP-87167
IM illumination
expansion base
OP-87168
IM illumination
bracket
OP-87169
IM illumination
bracket
(for CA-DXW7)
(for CA-DXW5A)
Options (others)
OP-87501
Precision fixturing
base
Options (stage glass)
OP-87677
Stage glass
OP-87678
Sapphire glass
OP-87679
Offset glass
[System Configuration Diagram]
Head
IM-6120
Controller
IM-6600E
Monitor
Statistics/analysis
viewer
Editor software
PC
CAD import module
Inkjet printer
26
Data transfer
software
Specifications
IM-6600E
IM-6120
Controller
Head
Model
Image pickup device
Display
Light receiving lens
Wide-field measurement mode
High-precision measurement mode
Field of view
Minimum display unit
Repetition accuracy
Measurement accuracy (±2σ)
Wide-field measurement mode
High-precision measurement mode
Wide-field measurement mode
High-precision measurement mode
External remote input
Comparator output (OK/NG/FAIL)
LAN
USB 2.0 series A
Hard disk drive
Operating ambient temperature
Operating ambient humidity
Transparent
Ring
External
Moving range
Moving range
Withstand load
Voltage
Power consumption
Controller
Head
External output
Record
Resistance to environment
Illumination system
Z stage
X stage
Power supply
Weight
1" 6.6 mega pixel CMOS
10.4" LCD monitor (XGA: 1024 x 768), external monitor connectable (clone output)
Double telecentric lens
ø100 x 200 mm
25 x 125 mm
0.1 μm
W/o stage movement: ±1 μm With stage movement: ±2 μm
W/o stage movement: ±0.5 μm With stage movement: ±1.5 μm
W/o binding: ±5 μm*1 With binding: ±(7 + 0.02 L) μm*2
W/o binding: ±2 μm*3 With binding: ±(4 + 0.02 L) μm*4
No-voltage input (with and without contact)
Relay output / Rated load: 24 VDC 0.5 A / ON resistance: 50 mΩ or less
RJ-45 (10BASE-T/100BASE-TX/1000BASE-T)
6 ports (Front: 2, Rear: 4)
250 GB
+10 to 35°C
20% to 80% RH (no condensation)
Telecentric transparent illumination (green LED)
Four division (white LED)
Externally connected illumination
30 mm (electric)
100 mm (electric)
1 kg
100 to 240 VAC 50/60 Hz
215 VA max.
Approx. 8 kg
Approx. 28 kg
*1 In the range of ø80 mm from the centre of the stage at the operating temperature range of +23 ±1°C at the focused focal point position
*2 In the range of ø80 x 180 mm from the centre of the stage at the operating temperature range of +23 ±1°C at the focused focal point position
(L = amount of stage movement in mm units)
*3 In the range of ø20 at the operating temperature range of +23 ±1°C at the focused focal point position
*4 In the range of ø20 x 120 mm at the operating temperature range of +23 ±1°C at the focused focal point position (L = amount of stage movement in mm units)
Measurement points
Pattern search (Profile tracking function)
Registration of measurement configuration
Measurement time
Distance measurement
Basic measurement function
Angle measurement
Calculation
Point
Conjunction edge
Virtual line function
Line
Circle
Pitch measurement
Pitch angle
Application tool
Width measurement
Thickness measurement
Special tool
Shape tolerance
GD&T
Orientation tolerance
Position tolerance
Point
Line
Element tool
Circle
Profile extraction
Special tool
Manual measurement
Coordinate system configuration
Batch configuration of tolerance
Element list editing
Measurement setting data binding function
DXF export function
99 points max. (99 x 9 points possible when the measurement setting binding function is used)
XYθ (with 360° rotary position compensation)
1000 or more*5
2 sec*6
8 types (point-point/line-point/line-line/circle-point/circle-line/circle-circle/circle/arc)
Provided
Provided
Middle point/intersection
Line conjunction/circular conjunction
6 types (midline/perpendicular line/parallel lines/tangent line/line passing through the point/approximate line)
Middle circle/approximate circle/auxiliary circle/inscribed and circumscribed circle
Line/circumference
Line/circumference
Edge width
Thickness measurement/gap measurement between inner and outer diameters
Rounded corner/curved surface/oval/reticle/point position/perimeter/area/screw
Straightness/circularity/profile
Squareness/parallelism
Point position/concentricity
Point (on a line or arc) / maximum/minimum (rectangle, circle, arc)
Line/centre line/peak line
Circle/arc/peak circle/peak arc
Provided
Automatic generation/gauge line
Provided
Provided
Provided
Provided
Provided
Provided
*5 Depending on the measurement setting data and number of data pieces being stored *6 W/o pattern search, applied measurement, and stage movement
Dimensions
Unit: mm
264
Head
IM-6120
Controller
IM-6600E
586
343.3
243
(343 when X stage is maximally moved)
482
173
322
27
General-purpose Model
Just place and press General-purpose type
image dimension measurement system
A totally new dimension measurement system born from
a new concept which eliminates the need for X-Y stages.
With a built-in ø100 optical lens,
this model enables all points in the entire field of view
to be measured in a batch.
Field of view: ø100 mm
IM-6015/6025
High-precision Model
Just place and press even for micro machined parts
High-precision type image dimension measurement system
An innovative stage designed for reducing measurement
time achieves place-and-press measurement even for
micro machined parts.
99 points can be measured in seconds
without concerns of target placement and focus.
Repetition accuracy: ±0.1 μm
IM-6140
Please visit:
www.keyence.com
SAFETY INFORMATION
Please read the instruction manual carefully in
order to safely operate any KEYENCE product.
KEYENCE CORPORATION
1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan
AUSTRIA
Phone: +43 22 36-3782 66-0 Fax: +43 22 36-3782 66-30
BELGIUM
Phone: +32 1 528 1222 Fax: +32 1 520 1623
BRAZIL
Phone: +55-11-3045-4011 Fax: +55-11-3045-5219
CANADA
Phone: +1-905-366-7655 Fax: +1-905-366-1122
CHINA
Phone: +86-21-68757500 Fax: +86-21-68757550
CZECH REPUBLIC
Phone: +420 222 191 483 Fax: +420 222 191 505
FRANCE
Phone: +33 1 56 37 78 00 Fax: +33 1 56 37 78 01
Phone: +81-6-6379-2211
GERMANY
Phone: +49 61 02 36 89-0 Fax: +49 61 02 36 89-100
HONG KONG
Phone: +852-3104-1010 Fax: +852-3104-1080
HUNGARY
Phone: +36 1 802 73 60 Fax: +36 1 802 73 61
INDIA
Phone: +91-44-4963-0900 Fax: +91-44-4963-0901
ITALY
Phone: +39-02-6688220 Fax: +39-02-66825099
JAPAN
Phone: +81-6-6379-2211 Fax: +81-6-6379-2131
KOREA
Phone: +82-31-789-4300 Fax: +82-31-789-4301
MALAYSIA
Phone: +60-3-2092-2211 Fax: +60-3-2092-2131
MEXICO
Phone: +52-81-8220-7900 Fax: +52-81-8220-9097
NETHERLANDS
Phone: +31 40 20 66 100 Fax: +31 40 20 66 112
POLAND
Phone: +48 71 36861 60 Fax: +48 71 36861 62
ROMANIA
Phone: +40 269-232-808 Fax: +40 269-232-808
SINGAPORE
Phone: +65-6392-1011 Fax: +65-6392-5055
SLOVAKIA
Phone: +421 2 5939 6461 Fax: +421 2 5939 6200
SLOVENIA
Phone: +386 1-4701-666 Fax: +386 1-4701-699
SWITZERLAND
Phone: +41 43-45577 30 Fax: +41 43-45577 40
TAIWAN
Phone: +886-2-2718-8700 Fax: +886-2-2718-8711
THAILAND
Phone: +66-2-369-2777 Fax: +66-2-369-2775
UK & IRELAND
Phone: +44-1908-696900 Fax: +44-1908-696777
USA
Phone: +1-201-930-0100 Fax: +1-201-930-0099
WW1-1013
The information in this publication is based on KEYENCE’s internal research/evaluation at the time of release and is subject to change without notice.
Copyright (c) 2013 KEYENCE CORPORATION. All rights reserved.
IM6120-WW-C-GB 1023-1 600B66 Printed in Japan
*
6
0
0
B
6
6
*

Similar documents

×